The Cash Valve B Series, Type E-55, Type PBE-1, Type PBE-2, and Type PBE-5

Cash Valve is a leading manufacturer of pressure regulating and back pressure valves offering products for steam, air/gas, liquid, and cryogenic applications. Temperatures range between cryogenic up through 800°F, and materials of construction are offered with iron, brass, bronze, carbon and stainless steel depending on your application. Products range in size from 1/8" - 2" for threaded NPT connections and up through 6 inches for flanged configurations. 

For more information about Cash Valve in Florida, the Caribbean, and  Puerto Rico, contact Classic Controls, Inc. by calling 863-644-3642 or by visiting their web site at https://classiccontrols.com. 

Cash Valve: Industrial Regulators and Back Pressure Valves for Air, Gas, Steam, Water and Oil Service

Cash Valve

Cash Valve regulators and valves are designed for pressure regulation and back-pressure. They are used for steam, air, gas, liquid, and cryogenic applications. These valves are available in multiple configurations, including a range of materials including iron, brass, bronze, carbon, and stainless steel. Standard sizes from 1/8” to 6” are available with working temperatures from cryogenic ranges to to 800° F. Diaphragms of various elastomers and metal configurations are available, depending on application.

CASH VALVE IS A LEADING MANUFACTURER OF PRESSURE REGULATING AND BACK PRESSURE VALVES OFFERING PRODUCTS FOR STEAM, AIR/GAS, LIQUID, AND CRYOGENIC APPLICATIONS.

For more information about Cash Valve, contact Classic Controls. Call them at 863-644-3642 or visit their website at https://classiccontrols.com.

Pressure Regulating Valves

pressure regulating valve
Pressure regulating valve, or pressure regulator.
One of many types.
Image courtesy Cash Valve
Pressure regulating valves (PRV) are common components of many processes and equipment. The function of a PRV is to maintain a desired outlet fluid pressure under varying conditions of supply pressure or outlet flow demand.

Many variants exist in the market, each specifically designed to address a range of process conditions or offset a performance characteristic deemed undesirable in another design. Each has a suitable place in the range of possible applications, with cost, size, construction material and complexity primary differences among the offerings.

In its simplest form, a pressure regulating valve (PRV) consists of a flow restricting element, a measuring element, and a setpoint element. Outlet pressure applies force to the measuring element, often a diaphragm. As the outlet pressure increases, the diaphragm will move the flow restricting element toward the closed position, reducing the flow from the inlet. The restricting element is commonly a plug, disk, or some other recognizable valve trim arrangement. The setpoint element, likely a spring, provides a counterbalancing force on the diaphragm. When the force applied to the diaphragm by the outlet pressure reaches equilibrium with the counterbalancing force applied by the spring, movement of the restricting element stops. In this way, outlet pressure is controlled without the need for electric power, sensors, transmitters, or even a process controller. The entire assembly is self-contained and requires little attention.

Selecting a PRV for an application requires coordinated consideration of process performance range, desired conditions, and valve attributes to produce a selection that will provide the desired service. A valve improperly selected for an application may perform poorly. Some of the items to be considered include:
  • PRV Type
  • Body size
  • Construction
  • Pressure Ratings
  • Maximum Flow Rate
  • Outlet Pressure Range
  • Accuracy
  • Inlet Pressure
  • Orifice Diameter
  • Response Speed
  • Turn-Down Ratio
A PRV is not a safety device. An independent means must be provided to protect the system from excessive pressure. Product specialists are a good source of help in selecting a properly sized and configured valve for an application. Share your fluid process control challenges with a product application specialist. Leverage your own process knowledge and experience with their product application expertise to develop an effective solution.

Pressure Regulator Valve or Back Pressure Regulator - Appropriate Application

pressure regulating valve pressure regulator
One of many available configurations
for a pressure regulating valve.
Courtesy Cash Valve
Fluids move throughout processes, driven by pressure produced with mechanical or naturally occurring means. In many cases the pressure generated by the driving source is substantially greater than what may be desired at particular process steps. In other cases, the operation may dictate that a minimum pressure be maintained within a portion of the process train. Both cases are handled by the appropriate valve type, designed specifically to regulate pressure.

A pressure regulating valve is a normally open valve that employs mechanical means, positioning itself to maintain the outlet pressure set on the valve. Generally, this type of valve has a spring that provides a countervailing force to the inlet pressure on the valve mechanism. An adjustment bolt regulates the force produced by the spring upon the mechanism, creating an equilibrium point that provides flow through the valve needed to produce the set outlet pressure. A typical application for a pressure regulator is to reduce upstream or inlet pressure to a level appropriate for downstream processing equipment.

Back pressure valves are normally closed, operating in a logically reversed fashion to pressure regulators. Where pressure regulators control outlet pressure, a back pressure valve is intended to maintain inlet pressure. Similar internals are present in the back pressure valve, with the valve action reversed when compared to a pressure regulator. An inlet pressure reduction in the back pressure valve will cause the valve to begin closing, restricting flow and increasing the inlet pressure. A representative application for a back pressure valve is a multi-port spray station. The back pressure valve will work to maintain a constant setpoint pressure to all the spray nozzles, regardless of how many may be open at a particular time.

Both of these valve types are available in an extensive array of sizes, capacities, pressure ranges, and materials of construction to accommodate every process requirement. Share your fluid control challenges with a process control specialist. Combining your process knowledge with their product application expertise will produce effective solutions.