Showing posts with label flow control. Show all posts
Showing posts with label flow control. Show all posts

Comparing Industrial Butterfly Valves: Rubber Lined, High Performance, and Offset Designs

Comparing Industrial Butterfly Valves: Rubber Lined, High Performance, and Offset Designs

Butterfly valves play a vital role in industrial fluid control systems, efficiently regulating flow across a wide range of applications. Rubber-Lined (General-Purpose) Butterfly Valves—and High-Performance Butterfly Valves (including Double and Triple Offset designs) stand out due to their unique designs and specific uses. Understanding the differences in valve style, construction, and application is crucial for selecting the most suitable valve for a given industrial need.

Rubber-Lined (General-Purpose) Butterfly Valves feature a straightforward, robust design ideal for low-pressure and low-temperature environments. In these valves, the stem is centered in the middle of the disc and seat, meaning the disc remains in constant contact with the seat throughout its operation. The valves consist of a disc mounted on a rotating shaft within a rubber-lined body, where the rubber lining acts as both the seat and the seal, ensuring tight shut-off when the disc closes. While this design offers simplicity and cost-effectiveness, it can lead to increased wear under higher pressures and temperatures due to the constant contact between the disc and seat. Industries such as HVAC, water treatment, and general manufacturing frequently employ rubber-lined butterfly valves due to their reliability and economical nature, especially in applications involving non-corrosive fluids at low pressures and temperatures.

In contrast, High-Performance Butterfly Valves are engineered for more demanding applications involving higher pressures and temperatures. These valves often incorporate advanced materials like stainless steel or specialized alloys for the disc and seat, enabling them to handle steam, gases, and corrosive chemicals. High-performance designs include Double Offset and Triple Offset Butterfly Valves, each offering enhanced capabilities for specific industrial needs.

Double Offset Butterfly Valves incorporate two distinct offsets: one from the centerline of the pipe and the second from the centerline of the seat cone. This design minimizes rubbing between the disc and seat during operation, reducing wear and enhancing seal longevity. The reduced friction allows these valves to operate effectively in higher pressure and temperature conditions than zero offset valves. Industries requiring reliable performance and extended service life under challenging conditions often utilize double offset designs.

Triple Offset Butterfly Valves add a third offset by designing the sealing components with a conical profile. This feature ensures that the disc contacts the seat only at the final point of closure, virtually eliminating wear and providing a torque-seated, zero-leakage valve. Constructed with metal-to-metal sealing surfaces, triple offset valves can withstand extreme temperatures and pressures. Industries such as petrochemical, power generation, and refining favor these valves for critical applications where safety and reliability are paramount.

Comparing these valves reveals key differences in design and operational capabilities. Rubber-lined valves, with their concentric design and elastomeric lining, offer simplicity and cost-effectiveness for general-purpose use but are limited to lower pressure and temperature applications. High-Performance Butterfly Valves, including double and triple offset designs, enhance performance for moderate to high-pressure systems thanks to their offset stems and improved sealing mechanisms.

Selecting the appropriate butterfly valve hinges on the application's specific requirements, including the type of fluid, pressure, temperature, and the necessity for tight shut-off. Rubber-lined butterfly valves present economical and effective solutions for general-purpose needs involving non-corrosive fluids at low pressures and temperatures. Conversely, High-Performance Butterfly Valves with double and triple offset designs are better suited for challenging environments where reliability and longevity are essential under higher pressures and temperatures.

Understanding the nuances of each valve type ensures optimal performance, safety, and cost-effectiveness in industrial fluid control systems. Engineers and operators can make informed decisions that enhance system efficiency and reliability by carefully considering valve style, construction, and application requirements.

Classic Controls  
+1 863-644-3642  

Control Valve Application Tips

Control Valve Application Tips

Incorrectly applied or sized control valve may have significant ramifications for operation, production, and, most importantly, safety. 

Here is a brief checklist of things to think about:
  1. Control valves are not isolation valves. Don't apply them as such.
  2. Always carefully choose the suitable construction material. Consider the valve components that come into contact with the process medium, such as the valve body, seat, and other "wetted" portions. Consider the control valve operational pressure and temperature exposure. Finally, examine the surrounding environment and any corrosives that may arise and affect the outside of the valve. 
  3. Place the flow sensor upstream of the control valve.  When the flow sensor is downstream of the control valve, it senses a less stable flow stream created by turbulent flow in the valve cavity. 
  4. Consider the degree of control you need and ensure that your valve's design will provide the controllability you require. 
  5. Excessive dead-band leads to hunting and poor control. The change of input signal necessary to induce a change in valve position is dead-band. Dead-band is affected by worn or loosely fitting mechanical linkages or a controller setting. It may also be affected by mechanical sensor tolerances, friction in the valve stems and seats, or an undersized actuator. 
  6. Think about stiction. Stiction is the propensity of valves that have had very little motion or have not moved at all to "stick." It is usually produced by the valves, packing glands, seats, or the pressure applied to the disk. 
  7. Make sure your loop controller is appropriately tuned.  Overshoot, undershoot, and hunting are symptoms of a poorly tuned controller. Check your proportional, integral, and derivative controller settings. Today, employing controllers with powerful, accurate auto-tuning capabilities that have replaced the old-fashioned trial and error loop tuning approach, is relatively simple. 
  8. Avoid oversizing your control valve.  Control valves are usually oversized for the flow loop they control. A tiny change in valve position has a considerable influence on flow. If the control valve is too large, only a fraction of its valve travel occurs, causing the valve to hunt, leading to severe wear. Always size a control valve to allow 70-90 percent of travel. 
  9. Consider the kind of control valve you're employing and its inherent flow characteristics. Flow properties vary greatly across valve types and their disks (or profiles). The flow characteristic is the change in flow rate in response to a change in valve position. The linear features of globe control valves are preferable, while the non-linear flow characteristics of butterfly and gate valves might pose control issues. Manufacturers add specifically designed disks or flow orifices that provide a custom flow profile to establish a linear flow characteristic via a non-linear control valve.
Classic Controls
https://classiccontrols.com
+1 863-644-3642

Application of Non-Invasive Flow Meter Technology to Extreme Temperature Lines

WaveInjector ultrasonic flow meter
One configuration of Flexim WaveInjector, allowing
non-invasive flow measurement at extreme temperatures.
Image courtesy Flexim Americas Corp.
The development of condensate in super heater and re-heater drains can lead to trouble in combined cycle and cogeneration plants with heat recovery steam generators (HRSGs). The need to reliably detect and measure condensate in these drain lines has emerged as an area needing attention.

The Problem

Heat recovery steam generators were never designed for cyclic service. The move toward renewable energy resources (such as wind and photovoltaic), in tandem with the ability of the combined cycle plant to start-up and stop quickly, is expanding the role of the combined cycle plant as a backup source of power. With frequent starts/stops condensate management can be challenging. Draining the condensate is critically important for the safe and reliable operation of the boiler. While the problem of condensate drainage has been around for years, the problem is greater now in installations with a higher frequency of cycling. The importance of finding a good solution for detecting condensate in the HRSG drain lines is growing.

Boiler manufacturers address this situation through the use of condensate pots, level instruments, site glasses, and valves. None of these technologies provide a satisfactory combination of reliability, economy, and efficiency. Knowing when steam converts to water is difficult with this approach. Plus, over cautious systems sometimes release steam instead of condensate, wasting energy. A more reliable and consistent way to sense the presence of water in drain lines had to be found.

The Solution

By designing specialized mounting and tooling, modifying their sensing diagnostics, putting in hundreds of hours of field testing, and investing hundreds of hours improving their firmware for water detection, the manufacturer Flexim developed an ultrasonic flow meter that elegantly and reliably solves the HRSG drain line problem.

These clamp-on sensors work by measuring the transit-time difference of an ultrasonic signal, at varying flow velocities, through the process media. Ultrasonic, clamp-on flow meters have no moving parts, are not affected by density, and are mounted directly to the pipe in a non-invasive fashion.

The most challenging aspects of this application are the exposure of the sensing units to high temperature and the thick-walled pipes with small diameters commonly used for drains. To handle the high temperatures, specialized mounting and tooling were developed for the sensor allowing for pipe temperatures up to 750 deg. F. To overcome the small diameter / thick pipe issue, Flexim engineers reconfigured the sensor’s firmware to change from measuring flow rate, and instead measure noise (decibels) as an innovative way to distinguish steam from water.

Flexim’s unique ability to measure the presence of liquid in condensate drain pipes is a revolutionary development. This valuable solution helps customers run longer and safer, minimizing downtime. Share your measurement challenges with process measurement specialists, leveraging your own knowledge and experience with their product application expertise to develop an effective solution.

When to Use a Globe Valve for Fluid Process Control

heavy duty industrial control globe valve with pneumatic actuator
Heavy duty industrial globe valve with pneumatic actuator
Masoneilan brand of GE
Industrial process control often involves the regulation of fluid flow. There are almost uncountable types and variants of flow control valves, each with a particular set of attributes that can make it the advantageous choice to meet certain applications.

When the process calls for controlling flow over a range of possible values, known as throttling, a globe valve may be a good candidate for the application.

Globe valves are characterized by the change in direction of fluid flow as it passes through the valve and the plug or disk positioned in an opening through which fluid must pass. The plug is connected to a stem extending to the exterior of the valve body through the bonnet. Movement of the stem will reposition the plug in relation to the opening, providing a successively larger or smaller opening area through which fluid can pass.
diagram of globe valve
Simple globe valve diagram
Courtesy Wikipedia
Globe valves are available in tee, angle, and wye configurations, as well as an enormous range of special configurations to suit specific applications.
What are some potential advantages of globe valves?

  • Good throttling and shutoff capability
  • Comparatively easy maintenance
  • Comparatively short travel of plug from open to closed position
  • Seats can usually be resurfaced when worn
What are some limiting factors for globe valves?

  • Higher valve pressure drop than some other designs
  • No straight through fluid path
  • Comparatively higher actuator torque requirements to operate valve
When flow throttling capability is the overriding concern for an application, a globe valve could be a good candidate for consideration. Share your flow control challenges with product specialists. Combining your process knowledge with their product application expertise will produce effective solutions.