Tunable Diode Laser Spectrometers (TDLS) play a pivotal role in modern industrial combustion processes by delivering precise, real-time measurements of critical gases such as oxygen (O₂) and carbon monoxide (CO). These measurements help operators optimize combustion efficiency, reduce harmful emissions, and improve operational safety. Unlike other gas analysis technologies, TDLS provides quick, in-situ analysis with high specificity to individual gases, which makes it an invaluable tool for facilities reliant on controlled combustion, including refineries, chemical plants, and power generation sites.

TDLS technology's heart lies using a tunable diode laser as the light source. The laser precisely targets specific gas molecules in the combustion stream, causing them to absorb the light at wavelengths unique to each gas. By carefully tuning the laser, TDLS can accurately measure gas concentrations without interference from other gases or particulates. This selectivity is essential for gases like O₂ and CO, where accurate readings can directly affect the efficiency and safety of a process. 

Oxygen levels serve as a primary indicator of fuel efficiency in a combustion process. Too much oxygen, or "excess air," results in energy wastage and increases operational costs, while too little can lead to incomplete combustion, producing high levels of CO and other toxic byproducts. TDLS systems continuously monitor O₂ levels, giving operators the data to make real-time adjustments that ensure an optimal air-to-fuel ratio. This precision improves energy efficiency and reduces the emission of pollutants, contributing to environmental sustainability.

Similarly, carbon monoxide monitoring plays a vital role in combustion optimization. High CO levels signal inefficient combustion, often stemming from poor burner performance, blockages, or incorrect airflow settings. By providing accurate CO readings, TDLS helps operators detect issues before they escalate into safety hazards or cause costly inefficiencies. Maintaining low CO levels enhances combustion quality and limits greenhouse gas emissions, a growing concern for industrial facilities facing stringent environmental regulations.

In addition to efficiency and emissions control, TDLS systems contribute significantly to safety within combustion environments. Furnaces and heaters are high-risk areas where an accumulation of combustible gases can lead to hazardous situations. By supplying continuous, real-time data on oxygen and CO levels, TDLS enables operators to act quickly when conditions deviate from safe operating ranges. This level of control is essential in furnaces and process heaters, where maintaining stable combustion parameters is crucial for preventing explosions or accidental shutdowns. For plants where downtime directly impacts profitability, TDLS provides the reliability needed to sustain uninterrupted operations safely.

TDLS technology's versatility extends beyond refineries and power plants. It has applications in industries where precise combustion control is necessary, such as steel production, glass manufacturing, and cement processing. Each of these industries benefits from the improved fuel efficiency and enhanced emissions control that TDLS provides, making it a versatile tool across various sectors focused on high-temperature processing.

Among the TDLS options available on the market, the Yokogawa TruePeak TDLS 8000 stands out for its cutting-edge features designed to address the specific needs of modern industrial environments. The TDLS 8000 offers a speedy response time, crucial for industries where real-time gas monitoring can determine the difference between optimal and inefficient combustion. Its design incorporates a highly robust, single-laser configuration that enables accurate gas measurements even in harsh environments, making it an ideal choice for high-stress applications. Yokogawa's TruePeak TDLS 8000 operates with an in-situ measurement system, eliminating the need for sample extraction or conditioning, allowing direct monitoring of gases in the process stream, and reducing maintenance requirements. This in-situ approach enhances measurement accuracy, making the TDLS 8000 a superior choice for operators seeking precise, hassle-free gas analysis.

Further, Yokogawa has equipped the TDLS 8000 with advanced diagnostic capabilities that support predictive maintenance strategies. The device continuously monitors its health status, alerting operators to potential issues before they disrupt operations. These diagnostics help maintain the system's performance, ensuring the continuous reliability of data and minimizing the need for manual checks. This feature reduces the overall maintenance costs and ensures uninterrupted operation, a valuable benefit for industries dependent on high process efficiency.

Yokogawa's TruePeak TDLS 8000 reflects the advancements in TDLS technology, offering a robust solution for industries needing accurate, real-time gas analysis. Its capabilities in optimizing combustion efficiency, lowering emissions, and enhancing safety make it a critical asset for facilities aiming to meet high environmental standards and achieve operational excellence.

Classic Controls
+1 863-644-3642
https://classiccontrols.com

The Yokogawa TDLS8100 Tunable Diode Laser Spectrometer

Yokogawa’s new TDLS8100 continues to house all of the industry’s leading features from the TDLS8000 but now only requiring a single-flange installation. An in-situ measurement with a probe removes sample extraction and conditioning requirements and is ideal for various aggressive process conditions.

Built upon Yokogawa’s second generation of TDLS analyzers, the platform still retains its improved reliability, ease of installation, and reduced maintenance requirements. Still, it now does so with a lower total installed cost for O2, CO/CH4, and NH3 measurements.

For more information contact Classic Controls. Call them at +1 863-644-3642 or visit their website at https://classiccontrols.com.

Tunable Diode Laser Spectrometers Improve Combustion and Heating Process Performance

Yokogawa TDLS 8000
Manufacturing facilities continue to explore ways to optimize processes by saving energy, reducing CO2 emissions, and improving safety. An area of plant investment that generally pays great dividends is in the optimization of combustion. By precisely controlling the air-fuel ratio, positive outcomes in fuel savings, emissions, regulatory issues, and safety are realized.

The implementation of a process instrument called a "tunable diode laser spectrometer" (TDLS) gives plant operators an excellent advantage in the management of combustion gases.

Yokogawa TDLS 220
Tunable diode laser spectrometers are laser-based gas analyzer which provide a quickly updating optical analysis. The TDLS line offers measurements for process gas, flue gas, impurity analysis, custody transfer, and safety with in-situ and extractive methods supported. They utilize laser absorption spectroscopy to detect and measure the concentration of O2, CO, CH4, NH3, H2O (and many more NIR absorbing gases) in combustion and heating processes.

Tunable diode laser spectrometers non-contact sensors are are optimal for use in corrosive, abrasive and condensing applications in the oil, petrochemical, electric power, iron and steel, and other industries.

For more information on tunable diode laser spectrometers, contact Classic Controls by calling 863-644-3642 or visit https://classiccontrols.com.

Laser Spectroscopy Applied to Oxygen Measurement



Combining the analytical function of laser spectroscopy with the simple installation package of an industrial transmitter, the Sick TRANSIC100LP provides direct real time in-process oxygen measurements in a wide range of industrial processes. The short video shows how the unit is easy to install and uncomplicated to operate as part of a process measurement and control system.

Fast results and low maintenance are hallmarks of TRANSIC100LP operation. There are no sample prep requirements and no consumables. Sick explains the operating principle of the transmitter in their technical data sheet...
"The TDLS Tunable Diode Laser Spectroscopy is primarily used in high-end gas analyzers and is characterized by its highly selective measurement capability. The oxygen properties are used for O2 measurement: That means O2 atoms in the near infrared range are stimulated at specific wavelengths. A laser diode modulates the radiation precisely over an absorption peak. The high-energy radiation transfers energy to the O2 atoms and the signals becomes weaker. In the measuring probe, the laser beam hits the O2 atoms and is weakened according to the concentrations of oxygen present there. A receiver measures the intensity of the arriving radiation and accurately determines the absorption. One distinct advantage of laser spectroscopy is it´s insensitivity to possible interference. For O2 in particular, there is no absorption of other gases in the range of sampled absorption peaks."
Watch the video for more detail and some application examples. Share your gas analysis requirements and challenges with process measurement specialists, combining your own process knowledge and experience with their product application expertise to develop effective solutions.