An educational blog sponsored by Classic Controls focusing on education and training for the process control, instrumentation, and industrial valve community.
Nitrogen Generator Animation Video - Pressure Swing Adsorption
Nitrogen is utilized throughout the industrial and commercial sectors It is incorporated as part of many compounds used to make a wide range of products. Nitrogen is also used as a cooling medium and as a means to isolate flammable or reactive compounds from oxygen.
There are several methods employed to generate or provide nitrogen, each with certain aspects making them advantageous to a certain range of applications. Convenience, reliability of supply, space, cost, energy consumption, purity, and a host of other factors can weigh on the decision for nitrogen supply.
Parker Balston, a globally recognized manufacturer of gas process equipment, employs pressure swing adsorption in some of its nitrogen generating equipment. The video illustrates the process and the brochure included below details the product offering for a wide range of applications. Nitrogen generation on site can provide an effective and economic means of providing a clean nitrogen supply for industrial operations. Share your requirements with product application specialists to see how a nitrogen generator system can benefit your operation.
VigilantPlant Solutions Partner Program
![]() |
| Classic Controls - Authorized Systems Integrator under Yokogawa VigilantPlant Solutions Partner Program Image courtesy of Yokogawa |
Whether considering a new installation, or upgrading in-place systems, share your plans and challenges with process control and automation experts. Leverage your own experience and knowledge with their product application expertise to develop effective solutions.
ASCO Fluid Automation Applications in Power Plants
![]() |
| ASCO products have applications throughout the power generation industry. |
ASCO Solenoid Valves
Ideal for steam, air, or liquid flows. Throughout the power plant, our solenoid valves provide superior service in areas such as SO2 scrubbing, turbine lubrication systems, and igniter burner No. 2 fuel lines to name a few.Numatics FRLs
Filters, regulators, and lubricators treat air quality and pressure in your plant’s pneumatic system. Apply them to control pressure or meet filtration requirements for your pneumatic equipment. These high-performance products are available in multiple configurations, including electronic regulators.ASCO Angle-Body Piston Valves
Well suited to replace ball valves in air, water, and steam applications with pipe sizes 2 1/2" or smaller and up to 150 psi. This compact solution reduces cost of ownership, eliminates water ham- mer, and creates tight shutoff in both directions. Available with limit switches, AS-interface®, and DeviceNetTM protocols, Class I, Div. 2 HS Series position indicators, and low power solenoids.ASCO Dust Collector Valves
ASCO integral or remote pilot valves are especially designed for dust collector applications, combining high flow, long life, and extremely fast opening and closing to produce reliable and economical operation. Valves with quick mount connections eliminate time consuming thread cutting and sealing.ASCO Pressure Sensors
A range of high-quality sensors with long-life designs and ensured repeatability, these signal when process media reach pressure set points. They play a vital part throughout the entire power generation process.ASCO Redundant Control System
The ASCO RCS is a redundant pilot valve system that acts as a single 3-way valve. Features include the ability to perform automatic online testing of the redundant solenoid valves, automatic partial stroke testing of the process valve, and online maintenance capabilities. Use this product in high reliability or critical applications. Certified per IEC 61508 Parts 1 and 2 and are SIL 3 capable.ASCO Solenoid Pilot Valves
Designed to operate at high cycles or for long periods of dormancy, these 3 and 4-way models provide ensured action in demanding applications. Features include, manual operators, high flows, and explosion-proof options. Plus new 0.55 W models are perfect for networks with low power limitations. Brass and stainless steel versions available.Numatics Cylinders
A large range of high quality Numatics cylinders that can withstand the harsh environment of power generation systems. Whether you are operating a scrubber, bag house, or damper controls, Numatics cylinders are used to open and close large orifices in these systems. Available in 17 bore sizes from 1 1/2" to 24".Share your application challenges with a product specialist, combining your own process and facilities knowledge and experience with their product application expertise to develop an effective solution.
Labels:
Asco,
Caribbean,
energy,
Florida,
Georgia,
power generation,
Puerto Rico,
solenoid valve
Training Program for UPS Users
As part of their dedication to delivering power management equipment and systems that help maintain business operation, Ametek Solid State Controls provides a comprehensive training program for customers, to enable them to understand the operation of their equipment and derive the maximum value from its operation. This short video provides a synopsis of the training program and company philosophy that assure customers are empowered by their equipment, not burdened.
Share your power conditioning and backup power requirements with dedicated specialists, leveraging your own knowledge and experience with their product application expertise to develop effective solutions.
Labels:
backup power,
Caribbean,
Florida,
Puerto Rico,
South Georgia,
training,
uninterruptible power,
UPS
Wireless Transmitters In Process Measurement and Control
![]() |
| Industrial wireless temperature transmitter, one of many variants available for process measurement Image courtesy Yokogawa |
Wireless devices and wired devices can co-exist on the same network. The installation costs of wireless networks are decidedly lower than wired networks due to the reduction in labor and materials for the wireless arrangement. Wireless networks are also more efficient than their wired peers in regards to auxiliary measurements, involving measurement of substances at several points. Adding robustness to wireless, self-organizing networks is easy, because when new wireless components are introduced to a network, they can link to the existing network without needing to be reconfigured manually. Gateways can accommodate a large number of devices, allowing a very elastic range for expansion.
In a coal fired plant, plant operators walk a tightrope in monitoring multiple elements of the process. They calibrate limestone feed rates in conjunction with desulfurization systems, using target values determined experientially. A difficult process environment results from elevated slurry temperature, and the associated pH sensors can only last for a limited time under such conditions. Thanks to the expandability of wireless transmitters, the incremental cost is reduced thanks to the flexibility of installing new measurement loops. In regards to maintenance, the status of wireless devices is consistently transmitted alongside the process variable. Fewer manual checks are needed, and preventative measures may be reduced compared to wired networks.
Time Synchronized Mesh Protocol (TSMP) ensures correct timing for individual transmissions, which lets every transmitter’s radio and processor rest between either sending or receiving a transmission. To compensate for the lack of a physical wire, in terms of security, wireless networks are equipped with a combination of authentication, encryption, verification, and key management. The amalgamation of these security practices delivers wireless network security equal to that of a wired system. The multilayered approach, anchored by gateway key-management, presents a defense sequence. Thanks to the advancements in modern field networking technology, interference due to noise from other networks has been minimized to the point of being a rare concern. Even with the rarity, fail-safes are included in WirelessHART™.
All security functions are handled by the network autonomously, meaning manual configuration is unnecessary. In addition to process control environments, power plants will typically use two simultaneous wireless networks. Transmitters allow both safety showers and eyewash stations to trigger an alarm at the point of control when activated. Thanks to reduced cost, and their ease of applicability in environments challenging to wired systems, along with their developed performance and security, wireless industrial connectivity will continue to expand.
In a coal fired plant, plant operators walk a tightrope in monitoring multiple elements of the process. They calibrate limestone feed rates in conjunction with desulfurization systems, using target values determined experientially. A difficult process environment results from elevated slurry temperature, and the associated pH sensors can only last for a limited time under such conditions. Thanks to the expandability of wireless transmitters, the incremental cost is reduced thanks to the flexibility of installing new measurement loops. In regards to maintenance, the status of wireless devices is consistently transmitted alongside the process variable. Fewer manual checks are needed, and preventative measures may be reduced compared to wired networks.
Time Synchronized Mesh Protocol (TSMP) ensures correct timing for individual transmissions, which lets every transmitter’s radio and processor rest between either sending or receiving a transmission. To compensate for the lack of a physical wire, in terms of security, wireless networks are equipped with a combination of authentication, encryption, verification, and key management. The amalgamation of these security practices delivers wireless network security equal to that of a wired system. The multilayered approach, anchored by gateway key-management, presents a defense sequence. Thanks to the advancements in modern field networking technology, interference due to noise from other networks has been minimized to the point of being a rare concern. Even with the rarity, fail-safes are included in WirelessHART™.
All security functions are handled by the network autonomously, meaning manual configuration is unnecessary. In addition to process control environments, power plants will typically use two simultaneous wireless networks. Transmitters allow both safety showers and eyewash stations to trigger an alarm at the point of control when activated. Thanks to reduced cost, and their ease of applicability in environments challenging to wired systems, along with their developed performance and security, wireless industrial connectivity will continue to expand.
Share your connectivity challenges with process measurement specialists, leveraging your own process knowledge and experience with their product application expertise.
Calibration Standards
![]() |
| Field calibration instruments Image courtesy of Yokogawa |
Even if instruments are designed to withstand harsh physical conditions and last for long periods of time, routine calibration as defined by manufacturer, industry, and operator standards is necessary to periodically validate measurement performance. Information provided by measurement instruments is used for process control and decision making, so a difference between an instrument’s output signal and the actual process condition can impact process output or facility overall performance and safety.
In all cases, the operation of a measurement instrument should be referenced, or traceable, to a universally recognized and verified measurement standard. Maintaining the reference path between a field instrument and a recognized physical standard requires careful attention to detail and uncompromising adherence to procedure.
Instrument ranging is where a certain range of simulated input conditions are applied to an instrument and verifying that the relationship between input and output stays within a specified tolerance across the entire range of input values. Calibration and ranging differ in that calibration focuses more on whether or not the instrument is sensing the input variable accurately, whereas ranging focuses more on the instrument’s input and output. The difference is important to note because re-ranging and re-calibration are distinct procedures.
In order to calibrate an instrument correctly, a reference point is necessary. In some cases, the reference point can be produced by a portable instrument, allowing in-place calibration of a transmitter or sensor. In other cases, precisely manufactured or engineered standards exist that can be used for bench calibration. Documentation of each operation, verifying that proper procedure was followed and calibration values recorded, should be maintained on file for inspection.
As measurement instruments age, they are more susceptible to declination in stability. Any time maintenance is performed, calibration should be a required step since the calibration parameters are sourced from pre-set calibration data which allows for all the instruments in a system to function as a process control unit.
Typical calibration timetables vary depending on specifics related to equipment and use. Generally, calibration is performed at predetermined time intervals, with notable changes in instrument performance also being a reliable indicator for when an instrument may need a tune-up. A typical type of recalibration regarding the use of analog and smart instruments is the zero and span adjustment, where the zero and span values define the instrument’s specific range. Accuracy at specific input value points may also be included, if deemed significant.
The management of calibration and maintenance operations for process measurement instrumentation is a significant factor in facility and process operation. It can be performed with properly trained and equipped in-house personnel, or with the engagement of subcontractors. Calibration operations can be a significant cost center, with benefits accruing from increases in efficiency gained through the use of better calibration instrumentation that reduces task time.
Labels:
calibration,
Caribbean,
field instruments,
Florida,
Georgia,
process measurement,
Puerto Rico,
ranging
Rotary and Linear Damper Drives for Control of Combustion Air and Flue Gas
![]() |
| Electro-hydraulic damper drive, with self contained pump, power unit, and positioner Image courtesy of Rexa |
Damper Operator (Drives) Types :
Damper drives can be one of three types: pneumatic, electric, or electro-hydraulic.
- Pneumatic - These damper operators employ compressed air as the motive force when positioning a connected damper.
- Electric - These operators rely on electric power to operate a drive mechanism, commonly a motor and gear assembly for damper positioning.
- Electro-hydraulic - Damper operators of this type combine an electrically operated pump that is precisely controlled. The pump moves a hydraulic fluid through a connected mechanism, such as a dual acting piston, to set the damper position.
The Goal for Selecting the Best Drive Technology:
Reduced emissions, lower fuel consumption and improved boiler draft control.
Ways to achieve this goal may include drive operating features:
- High speed continuous modulation
- Quick response to plant demand
- Reliability in high temperature environments
- Precise damper positioning, with no drift once positioned
- Simple commissioning and diagnostics
- Low operating cost
- Minimal maintenance burden
Subscribe to: