Siemens has discontinued their 353 SLC controller. The 353 was used in many process applications for many years. It's discontinuation leaves many companies without an alternative.
Don't worry - you don't have to turn to eBay looking for spare parts? There's a better solution - the Yokogawa YS1700 PID loop controller. The YS1700 is a drop-in SLC replacement for the Siemens 353 and will keep you off of eBay.
The YS1700’s powerful function block programming allows for custom strategies to control many demanding processes such as boilers and steam generators, PH control, dosing control, and many other demanding plant processes. For more information, visit this site.
An educational blog sponsored by Classic Controls focusing on education and training for the process control, instrumentation, and industrial valve community.
Understanding How Radiometric (Radiation-based) Level Measurement Works
Radiometric (also known as radiation-based) level measurement uses a very slightly radioactive isotope that emits focused gamma rays. A sensor, which is mounted on the opposite side of the vessel, receives this radiation. Because gamma rays are attenuated when penetrating matter, the sensor can calculate level, point level, density or mass flow from the intensity of the incoming radiation.
Advantages are:
For more information contact:
https://classiccontrols.com
863-644-3642
Advantages are:
- Maximum operational reliability even in the harshest environments
- Measurement is independent of pressure, temperature and product aggressiveness
- Measuring system can be installed on the outside of a vessel during ongoing production
For more information contact:
https://classiccontrols.com
863-644-3642
Classic Controls Becomes Associate Member of CARILEC
Classic Controls is very please to announce the company has been accepted as an Associate Member of CARILEC (Caribbean Electric Utility Services Corporation).
CARILEC is an association of electric services, dealers, manufactures and other stakeholders operating in the electricity industry in the Caribbean region, Central and South Americas and Globally.
CARILEC was established in 1989 with an original nine members as part of an electric utilities modernization project funded by USAID and implemented by NRECA under a five-year "Co-operative Agreement." Currently, CARILEC comprises a total of one hundred and six (106) members. This includes thirty five (35) Full Members that are electric utilities and sixty six (66) Associate Members that are companies involved in some aspect of servicing the electric utility business and four (5) Affiliate Members. The vision of CARILEC is "To be the Premier Association of Electric Utilities and Industry partners; facilitating the development of world class electric energy services for all peoples of the Caribbean."
Classic Controls is a total solutions, single-source provider of industrial process instruments for the entire Caribbean. Along with representing “best-in-class” manufacturers, Classic Control's employees are people driven by total customer satisfaction, with a field salesforce who are technically strong, conscientious, and who can properly apply, train, and support the products they apply.
CARILEC is an association of electric services, dealers, manufactures and other stakeholders operating in the electricity industry in the Caribbean region, Central and South Americas and Globally.
CARILEC was established in 1989 with an original nine members as part of an electric utilities modernization project funded by USAID and implemented by NRECA under a five-year "Co-operative Agreement." Currently, CARILEC comprises a total of one hundred and six (106) members. This includes thirty five (35) Full Members that are electric utilities and sixty six (66) Associate Members that are companies involved in some aspect of servicing the electric utility business and four (5) Affiliate Members. The vision of CARILEC is "To be the Premier Association of Electric Utilities and Industry partners; facilitating the development of world class electric energy services for all peoples of the Caribbean."
Classic Controls is a total solutions, single-source provider of industrial process instruments for the entire Caribbean. Along with representing “best-in-class” manufacturers, Classic Control's employees are people driven by total customer satisfaction, with a field salesforce who are technically strong, conscientious, and who can properly apply, train, and support the products they apply.Quarter Turn vs. Linear Industrial Valves
![]() |
| Linear control valve (Masoneilan) |
All valves operate by providing control of the position of an internal structure that impedes fluid passage to some degree. Generally, fluid flow at the valve can be characterized as one of three conditions, unrestricted (valve fully open), stopped (valve fully closed), and throttled (valve partially open). Process operational requirements will dictate whether just two (fully open and fully closed) or all three of those conditions will be needed. Many aspects of the fluid, the process, and the surrounding environment come into play when making an appropriate valve selection. Not always an easy task.
![]() |
| Solenoid valves are a type of linear valve. (ASCO) |
Linear valves are generally characterized by their straight line motion that is used to position the valve plug, disc, diaphragm or other flow controlling element. The shape, size, and arrangement of the linear valve trim is generally intended to empower the operator with a range of flow through the valve. Through its positioning, the linear valve is able to regulate fluid flow at a slower, but more accurate rate. The valves can move a disk or a plug into an orifice, or push a flexible material, such as a diaphragm, into the flow passage. Gate valves and globe valves are common examples of linear motion valves. A solenoid valve also acts as a specialized type of linear valve. Linear valves are best applied as flow controllers, and are often suited for frequent operation and repositioning.
![]() |
| Ball valves are examples of quarter turn valves. (QTR) |
Depending on the specific scenario, linear valves and quarter-turn valves are optimal choices for particular process environments. The accuracy of the linear valve and its ability to move in a linear fashion as opposed to a quarter-turn comes coupled with easy maintenance and decreased likelihood of cavitation. Both valve types enjoy widespread use and should generally not be viewed as competing designs for the same application. Each has a range of applications where it excels.
Contact Classic Controls for any industrial valve requirement by visiting https://classiccontrols.com or by calling 863-644-3642.
Happy 4th of July from Classic Controls
"America is much more than a geographical fact. It is a political and moral fact — the first community in which men set out in principle to institutionalize freedom, responsible government, and human equality."
Adlai Stevenson
Drying Compressed Air In Hazardous Atmospheres
In many industries, the atmosphere, though safe to breath, may be unsafe for an electrical spark. These areas often have pneumatically operated equipment for safety. And that equipment needs a source of clean dry air or as it is called in the industry, Instrument Grade Air. Plants typically have a centralized instrument grade air line that delivers air to the instruments that need it. However, oftentimes the instrument grade air is of inferior quality and contaminated with water. This air will benefit from a point of use drying system that guarantees instrument grade air. Traditional drying systems using PSA (Pressure Swing Adsorption) or refrigerant require expensive modifications to operate within hazardous areas. Air dryers made from hollow fiber membranes can dry compressed air without the use of electricity and are therefore safe for hazardous environments.Hazardous locations have or could potentially have high concentrations of flammable gases, vapors, combustible dusts or ignitable fibers and flyings. Refineries, chemical processing plants, mines and grain mills are examples of industries with hazardous atmospheres. Even a small spark can lead to a horrific explosion dangerous to equipment and workers in the area.
Read the rest of the Parker Balston white paper in the embedded document below, or download your PDF version of "Drying Compressed Air In Hazardous Atmospheres" here.
For more information, visit https://classiccontrols.com or call 863-644-3642.
University Campuses Greatly Reduce Energy Costs Retrofitting with Clamp-on Thermal Energy Meters
![]() |
| Flexim Clamp-on Thermal Meter |
Every university to some extent is now engaged in this process, and one of the first things that has to be addressed is the metering of distributed thermal energy. To effectively begin energy reduction initiatives, accurate and reliable thermal energy metering has to be in place.
Today, there is high priority for understanding that we need to be better stewards of energy consumption. Poor energy consumption harms the environment and creates much higher operating costs. Universities have become very involved in the move toward greener energy. Many universities began metering long ago while some are just beginning. Most are in the middle of the process.
![]() |
| Installation of clamp-on thermal meter (click for larger view). |
- Step 1: Cut insulation where transducers and RTD will be located.
- Step 2: Install stainless bands around pipe under insulation.
- Step 3: Install transducers and RTD.
- Step 4: Cover transducers and RTD with insulation and tape.
Many universities have gone through an evolution of trying to meter thermal energy consumption throughout their campus. The success of these ventures can be elusive when the meter chosen for the job doesn’t live up to expectations. Examples include insertion meters that over time will foul and meters that cannot respond to low velocities that are prevalent during off-peak metering.
On proven alternative is FLEXIM’s Thermal Energy / BTU Flow Meter. The technology, based upon FLEXIM's ultrasonic clamp-on meters, do not require shutdown and are very cost effective to install.
Clamp-on ultrasonic meters have been doing the job of BTU-metering for decades and the Flexim thermal energy meters are leading the effort towards more energy efficient buildings and facilities.
More than 150 colleges and universities throughout the country are using the FLEXIM product as their preferred thermal energy meter and attest to FLEXIM’s performance, reliability and support.
For more information on Flexim thermal energy products, contact Classic Controls by visiting https://classiccontrols.com or by calling 863-644-3642.
Labels:
campus,
Caribbean,
clamp-on,
college,
Flexim,
Florida,
flow meter,
Puerto Rico,
University
Subscribe to:
Posts (Atom)