Clamp-On Ultrasonic Flow Meters: Measure from the Outside of the Pipe


Conventional measuring systems such as differential pressure meters, electromagnetic flowmeters, vortex meters or Coriolis mass flowmeters require costly pipe modifications and experience increased wear resulting in frequent maintenance intervals. FLEXIM is the technology and market leader in the field of clamp-on ultrasonic flowmeters that eliminate the need for pipe entry points, eliminate wear,  and does not require shutdown for maintenance.

For more information, contact Classic Controls.
https://classiccontrols.com
863.644.3642

Industrial Flow Meter Selection

Industrial Flow Meter Selection
Flow meter selection chart. Click on image for larger view.

Many industrial process control operations require fluid flow measurement as an essential element in the design of the process. The proper application and installation of a flow meter as part of the fluid transfer system will provide accurate flow measurement.

Industrial flow meters use different technologies to measure fluid flow rates directly or indirectly. Some of the most common technologies for fluid flow measurement are vortex flow meters, magnetic flow meters, Coriolis flow meters and rotameters.

Each separate technology has attributes that can make it more suitable for certain applications. The selection of the most appropriate flow measurement technology for an application is an initial and crucial step in the design of a functioning fluid measurement system.

Selection criteria such as fluid temperature, pressure and velocity will be included in the selection process. Further considerations include whether the fluid may be abrasive, corrosive, clean or dirty. The state of the fluid, liquid or gas, must also be taken into account.

The table above provides general guidance on which technologies to consider, based on the above mentioned factors. This will help you to focus further research on product selection.

Contact Classic Controls with any industrial flow application you may have. Their application engineers will provide guidance and advice to assure the proper flow meter is chosen.

Classic Controls
https://classiccontrols.com
863-644-3642

Ultrasonic Clamp-On Flowmeter with SIL 2 Rating

SIL 2 capable clamp on ultrasonic flowmeter
FLUXUS F/G70X and F/G80X series meters
Image Courtesy Flexim
Measuring the flow quantity of gases and liquids is a common industrial processing task. There are numerous technologies available for measuring fluid flow, each with its own set of advantages and drawbacks for any particular application. Some of the technologies and methods have been in use for a very long time, with recent enhancements provided by electronics or smart sensor designs.

Ultrasonic flow measurement devices employ a comparatively recent technology to measure gaseous or liquid flow. Whether the transit time differential or Doppler method is utilized, ultrasonic flow meters have a distinctive characteristic in that they can be deployed in a form factor that does not require contact with the the process fluid, nor insertion in the fluid flow path. A common installation method is to clamp the ultrasonic transducer assembly onto the exterior of a process pipe. This makes the technology attractive for applications that involve adding a flow measurement point to an existing piping system.

Flexim, a globally recognized leader in ultrasonic flow measurement, offers a number of permanent and portable units for measuring liquid and gaseous flow rates. Some of their instruments have been certified as SIL 2 capable, along with a host of other third party certifications. The product range includes simple and accurate instruments designed for general industrial use, and extends to multi-beam units intended for applications, such as custody transfer of fluids, that require the highest accuracy and overall performance levels.

Share your flow measurement challenges and requirements with instrumentation specialists, combining your own process knowledge and experience with their product application expertise to develop effective solutions.


Magnetic Flow Meters: Principles and Applications

magnetic flow meter, magmeter, or flowmeter
Magnetic flowmeters are well suited for flow measurement
with conductive fluids.
Image courtesy Yokogawa
Fluid process control operations rely on the operator's ability to accurately determine qualities and quantities of liquid or gaseous materials. In terms of appraising and working with fluids (such as liquids, steam, and gases) the flow meter is a staple tool, with the simple goal of expressing the delivery of a subject fluid in a quantified manner. Measurement of media flow velocity can be used, along with other inputs, to determine volumetric or mass flow. The magnetic flow meter, also called a magmeter, is one of several technologies used to measure fluid flow.

In general, magnetic flow meters are sturdy, reliable devices able to withstand hazardous environments while returning accurate measurements to operators of a wide variety of processes. The magnetic flow meter has no moving parts. The operational principle of the device is powered by Faraday’s Law, a fundamental scientific principle stating that a voltage will be induced across any conductor moving at a right angle through a magnetic field, with the voltage being proportional to the velocity of the conductor. The principle allows for an inherently hard-to-measure quality of a substance to be expressed via the magmeter. In a magmeter application, the meter produces the magnetic field referred to in Faraday’s Law. The conductor is the fluid. The actual measurement of a magnetic flow meter is the induced voltage corresponding to fluid velocity. This can be used to determine volumetric flow and mass flow when combined with other measurements.

The magnetic flow meter technology is not impacted by temperature, pressure, or density of the subject fluid. It is however, necessary to fill the entire cross section of the pipe in order to derive useful volumetric flow measurements. Faraday’s Law relies on conductivity, so the fluid being measured has to be electrically conductive. Many hydrocarbons are not sufficiently conductive for a flow measurement using this method, nor are gases. On the other hand, water and aqueous solutions tend to exhibit sufficient conductivity to apply magmeter technology.

Magmeters apply Faraday’s law by using two charged magnetic coils; fluid passes through the magnetic field produced by the coils. A precise measurement of the voltage generated in the fluid will be proportional to fluid velocity. The relationship between voltage and flow is theoretically a linear expression, yet some outside factors may present barriers and complications in the interaction of the instrument with the subject fluid. These complications include a higher amount of voltage in the liquid being processed, and coupling issues between the signal circuit, power source, and/or connective leads of both an inductive and capacitive nature.

In addition to salient factors such as price, accuracy, ease of use, and the size-scale of the flow meter in relation to the fluid system, there are multiple reasons why magmeters are the unit of choice for certain applications. They are resistant to corrosion, and can provide accurate measurement of dirty fluids – making them suitable for wastewater measurement. As mentioned, there are no moving parts in a magmeter, keeping maintenance to a minimum. Power requirements are also low. Instruments are available in a wide range of configurations, sizes, and construction materials to accommodate various process installation requirements.

As with all process measurement instruments, proper selection, configuration, and installation are the real keys to a successful project. Share your flow measurement challenges of all types with a process measurement specialist, combining your own process knowledge and experience with their product application expertise to develop an effective solution.

Flow Measurement - Sometimes the Simple Solution is Best

variable area flow meter measures and indicates fluid flow directly
These variable area flow meters also permit visible
inspection of flowing media
Courtesy ERDCO Engineering Corp.
For process control and commercial or industrial applications, there are numerous methods of flow measurement from which to choose. Technologies range from very simple applications of physical principles to deployment of very specialized electronics and sensors. The available range of accuracy, response, and cost is quite broad, with a general expectation that higher cost will deliver better performance and accuracy.

Making the best instrument selection for a flow measurement application should include an assessment of what the operators really need in order to safely and effectively run the process or perform the task related to the measurement of fluid flow. Installing instrumentation with capabilities far beyond what is required is almost certainly a waste of financial resources, but may also have an unexpected impact on operators. Through the generation of data that, while accurate, does not provide any actionable information about process condition, operators can be misled, similar to the occurrence of a false or nuisance alarm. Some applications call for high accuracy, some do not. Define your informational needs and select instruments that will meet those needs.

There is a large array of applications that can be satisfied with simpler, less costly measurement technology. These devices often employ turbines or vanes to produce an indication of flow rate. Incorporated into some of the instruments is a means to visually observe the flowing liquid to verify color and clarity. Simple devices sometimes are intended only to indicate the presence of fluid flow, and whether the flow rate is high or low. Configurations are available that allow insertion into lines under pressure (hot tap) through a full port ball valve. Other variants with combinations of features and capabilities abound.

The selection range is enormous, so define your minimum needs first, then search for a compatible product. Your search can be enhanced by contacting an instrumentation specialist. Combining your process expertise with their broad product knowledge will produce effective solutions.



Operating Principles and Application of Vortex Flowmeters

vortex flow meter flowmeter
Vortex Flowmeter
Courtesy Yokogawa
To an untrained ear, the term “vortex flowmeter” may conjure futuristic, potentially Star Wars inspired images of a hugely advanced machine meant for opening channels in warp-space. In reality, vortex flowmeters are application specific, industrial grade instruments designed to measure an important element of a fluid process control operation: flow rate.

Vortex flowmeters operate based on a scientific principle called the von Kármán effect, which generally states that a fluid flow will alternately shed vortices when passing by a solid body. “Vortices” is the plural form of vortex, which is best described as a whirling mass, notably one in which suction forces operate, such as a whirlpool. Detecting the presence of the vortices and determining the frequency of their occurrence is used to provide an indication of fluid velocity. The velocity value can be combined with temperature, pressure, or density information to develop a mass flow calculation. Vortex flowmeters exhibit high reliability, with no moving parts, serving as a useful tool in the measurement of liquid, gas, and steam flow.

While different fluids present unique challenges when applying flowmeters, steam is considered one of the more difficult to measure due to its pressure, temperature, and potential mixture of liquid and vapor in the same line. Multiple types of steam, including wet steam, saturated steam, and superheated steam, are utilized in process plants and commercial installations, and are often related to power or heat transfer. Several of the currently available flow measurement technologies are not well suited for steam flow applications, leaving vortex flowmeters as something of a keystone in steam flow measurement.

Rangeability, defined as a ratio of maximum to minimum flow, is an important consideration for any measurement instrument, indicating its ability to measure over a range of conditions. Vortex flowmeter instruments generally exhibit wide rangeability, one of the positive aspects of the technology and vortex based instruments.

The advantages of the vortex flowmeter, in addition to the aforementioned rangeability and steam-specific implementation, include available accuracy of 1%, a linear output, and a lack of moving parts. It is necessary for the pipe containing the measured fluid to be completely filled in order to obtain useful measurements.

Applications where the technology may face hurdles include flows of slurries or high viscosity liquids. These can prove unsuitable for measurement by the vortex flowmeter because they may not exhibit a suitable degree of the von Kármán effect to facilitate accurate measurement. Measurements can be adversely impacted by pulsating flow, where differences in pressure from the relationship between two or more compressors or pumps in a system results in irregular fluid flow.

When properly applied, the vortex flowmeter is a reliable and low maintenance tool for measuring fluid flow. Frequently, vortex flow velocity measurement will be incorporated with the measurement of temperature and pressure in an instrument referred to as a multivariable flowmeter, used to develop a complete measurement set for calculating mass flow.

Whatever your flow measurement challenges, share them with a flow instrument specialist, combining your process knowledge with their product and technology expertise to develop effective solutions.


Transit Time Differential Ultrasonic Flow Measurement - How It Works

industrial process ultrasonic flow meter
Ultrasonic flow meter, transducer and control unit
Courtesy Flexim
The measure of flow is a pervasive task in fluid process control. There are several differing technologies employed for measuring fluid flow, each with its own set of performance and application attributes that might make it the advantageous choice for a particular operation.

Ultrasonic flow measurement uses several methods for determining the average velocity of a fluid. One of those methods employs the difference in the transit times of ultrasonic pulses travelling with the flow direction and against the flow direction. The flow velocity of the media will offset the transit times between the flow and counterflow measurements. The measured difference in transit times can be used to determine average flow velocity and, with additional processing, mass flow.

Ultrasonic flow meters are accurate and provide repeatable results, making them suitable for custody transfer operations, as well as many other process control applications. Little maintenance is required and the units have no moving parts. Measurement instruments are available with in-line or clamp-on mounting, providing a high level of installation and application flexibility.

The short video below provides a clear explanation of how transit time difference measurement works. Share your flow measurement challenges and requirements with a product application expert, combining your process knowledge with their product expertise to develop effective solutions.

 

Thermal Flowmeters with Constant Temperature Differential (∆T) Technology to Measure Mass Flow Rate of Air and Gases

thermal flow meter sensor Fox Thermal Instruments
Thermal Flow Meter
Sensor
Fox Thermal Instruments
Thermal flow meters use a constant temperature differential (∆T) technology to measure mass flow rate of air and gases. The thermal mass flow sensor consists of two Resistance Temperature Detectors (RTD’s). The sensor elements are constructed of a reference grade platinum wire wound around ceramic mandrels that are inserted into stainless steel or Hastelloy tubes.

The reference RTD measures the gas temperature. The instrument electronics
heat the mass flow sensor, or heated element, to a constant temperature and measures the cooling effect of the gas flow. The electrical power required to maintain a constant temperature differential is directly proportional to the gas mass flow rate. The microprocessor then linearizes this signal to deliver a linear 4 to 20mA signal.

One manufacturer, Fox Thermal Instruments, implements a
technology they call the Power Pro™ Sensor. Their sensor operates at a higher power level than other competitive thermal technologies, providing better response time and wider turndown. When compared to a typical differential pressure type flow meter, as shown to the right, the Power Pro™ Sensor offers better low flow or low end sensitivity. The Power Pro™ Sensor also provides exceptional accuracy at high velocities - up to 50,000 SFPM air.

The Fox DDC-Sensor™ is a new state of the art sensor technology used in the Fox Model FT1 Thermal Gas Flow Meter. The DDC-Sensor™, a direct digitally controlled sensor that is interfaced directly to the FT1 microprocessor for more speed and programmability.

Like the Power Pro™ Sensor, the DDC-Sensor™ accurately responds to changes in process variables (gas flow rate, pressure, and temperature) which are used by the microprocessor to determine mass flow rate, totalized flow, and temperature.

In addition to measuring flow, the DDC-Sensor™ provides a technology platform for calculating accurate gas correlations. The FT1 correlation algorithms allow the meter to be calibrated on a single gas in the factory while providing the user the ability to select other gases in the Gas-SelectX® gas menu. Fox’s Model FT1 with its DDC-Sensor™ and state-of-the-art correlation algorithms provide an accurate, multi-gas capable thermal flow meter for gas applications.


Selecting the Right Flow Meter Technology

Vortex Flow Meter - Yokogawa Corporation
Vortex Flow Meter
Courtesy Yokogawa Corp.
Magnetic Flow Meter - Yokogawa Corporation
Magnetic Flow Meter
Courtesy Yokogawa Corp.
Many industrial process control operations require fluid flow measurement as an essential element in the process design. Accurate flow measurement can be obtained with the proper application and installation of a flow meter as part of the fluid transfer system.

Industrial flow meters employ differing technologies to directly or indirectly measure fluid flow rates. Among the many available technologies for fluid flow measurement, vortex flow meters, magnetic flow meters, Coriolis flow meters, and rotameter flow meters are among some of the most common found in industry.

Coriolis Flow Meter - Yokogawa Corp.
Coriolis Flow Meter
Courtesy Yokogawa Corp.
Rotameter Flow Meters - Yokogawa Corporation
Rotameter Flow Meters
Courtesy Yokogawa Corp.
Each of the separate technologies have attributes which can make them more suitable to certain applications. Selecting the most appropriate flow measurement technology for an application is one of the initial and crucial steps to designing a well functioning fluid measurement system.

Selection criteria, such as fluid temperature, pressure, and velocity will be part of the selection process. Additional considerations include whether the fluid may be abrasive, corrosive, clean or dirty. The state of the fluid, liquid or gas, must also be considered.

The table below provides quick general guidance on which technologies to consider, based upon the factors outlined above. This will help you better focus further product selection research efforts.

Industrial Flow Meter Selection Table - Yokogawa Corporation
Flow Meter Technology Selection Table
Courtesy Yokogawa Corporation of America

Selecting the right device is not always an easy task, especially since it may be something that you do infrequently. Manufacturers often have knowledgeable local representatives that are experienced in this field and more than willing to contribute their expertise to your selection process.