Anguilla, Antigua & Barbuda, Aruba, Bahamas, Barbados, Bermuda, Bonaire, British Virgin Islands, Cayman Islands, Curaçao, Dominica, Dominican Republic, Grenada, Guadeloupe, Guyana, Haiti, Jamaica, Martinique, Montserrat, Puerto Rico, Saba, St. Barthélemy, St. Eustatius, St. Kitts & Nevis, St. Lucia, St. Maarten, St. Martin, St. Vincent & the Grenadines, Suriname, Trinidad & Tobago, Turks & Caicos Islands, US Virgin Islands.


Setting Limit Switches on AUMA SA Multi-Turn Actuators and SQ Part-Turn Actuators

AUMA SA Multi-Turn Actuator
AUMA SA Multi-Turn Actuator
Type SA multi-turn actuators and SQ part-turn actuators are the core products of the AUMA product portfolio.

AUMA SA electric multi-turn actuators are used for the automation of gate valves or globe valves.

AUMA SQ electric part-turn actuators are used where an automatic, electrically operated movement at a swing angle of less than 360 ° has to be implemented as it is the case for valves like butterfly and ball valves.

Below is a video that demonstrates how to set the limit switches for both SA and SQ.

This video is intended as a supplement to the operating instruction and/or manuals available from your local AUMA Representative.

Yokogawa TDLS8000 In-Situ Gas Analyzer

Yokogawa’s TDLS8000 houses all of the industry’s leading features in one robust device. The platform design is for in situ measurements which negate the need for sample extraction and conditioning. The non-contacting sensor allows for a variety of process types including corrosive, abrasive and condensing.

Features:
  • SIL2 TruePeak combined with smart laser Technology
  • Intuitive touchscreen HMI
  • HART and Modbus TCP communications standard
  • 8-stage auto-gain adapts to difficult applications
  • Fully field repairable with 50 days of data and spectra storage
  • Compact design for one-man installation without sacrificing ruggedness
  • Area classification Zone2/Div2 or Zone1/Div1
https://classiccontrols.com
863-644-3642

Wireless Remote Asset Monitoring & Control

SignalFire GatewaySignalFire’s unique patent-pending two-way mesh technology provides the power and stability needed for reliable data transfer over long node-to-node distances. They couple an innovative message-forwarding architecture with low-cost, high-power ISM-band radios, creating a simple, affordable system that’s easy to deploy. Their technology is ideal for applications calling for many assets widely dispersed (up to 4 miles point-to-point), such as flow, level, pressure, and temperature, and can control devices such as pumps, valves, fans, and lighting.

For more information on SignalFire, visit https://classiccontrols.com or call 863-644-3642.

Classic Controls: Your Total Solutions Provider for Instrumentation, Valves and Process Equipment

Classic Controls, Inc. is a total solutions, single-source provider of industrial process instruments serving Florida, southern Georgia, and the entire Caribbean. Along with representing “best-in-class” manufacturers, Classic Control's employees are people driven by total customer satisfaction, with a field salesforce who are technically strong, conscientious, and who can properly apply, train, and support the products they specify.

https://classiccontrols.com
863-644-3642

Application of Non-Invasive Flow Meter Technology to Extreme Temperature Lines

WaveInjector ultrasonic flow meter
One configuration of Flexim WaveInjector, allowing
non-invasive flow measurement at extreme temperatures.
Image courtesy Flexim Americas Corp.
The development of condensate in super heater and re-heater drains can lead to trouble in combined cycle and cogeneration plants with heat recovery steam generators (HRSGs). The need to reliably detect and measure condensate in these drain lines has emerged as an area needing attention.

The Problem

Heat recovery steam generators were never designed for cyclic service. The move toward renewable energy resources (such as wind and photovoltaic), in tandem with the ability of the combined cycle plant to start-up and stop quickly, is expanding the role of the combined cycle plant as a backup source of power. With frequent starts/stops condensate management can be challenging. Draining the condensate is critically important for the safe and reliable operation of the boiler. While the problem of condensate drainage has been around for years, the problem is greater now in installations with a higher frequency of cycling. The importance of finding a good solution for detecting condensate in the HRSG drain lines is growing.

Boiler manufacturers address this situation through the use of condensate pots, level instruments, site glasses, and valves. None of these technologies provide a satisfactory combination of reliability, economy, and efficiency. Knowing when steam converts to water is difficult with this approach. Plus, over cautious systems sometimes release steam instead of condensate, wasting energy. A more reliable and consistent way to sense the presence of water in drain lines had to be found.

The Solution

By designing specialized mounting and tooling, modifying their sensing diagnostics, putting in hundreds of hours of field testing, and investing hundreds of hours improving their firmware for water detection, the manufacturer Flexim developed an ultrasonic flow meter that elegantly and reliably solves the HRSG drain line problem.

These clamp-on sensors work by measuring the transit-time difference of an ultrasonic signal, at varying flow velocities, through the process media. Ultrasonic, clamp-on flow meters have no moving parts, are not affected by density, and are mounted directly to the pipe in a non-invasive fashion.

The most challenging aspects of this application are the exposure of the sensing units to high temperature and the thick-walled pipes with small diameters commonly used for drains. To handle the high temperatures, specialized mounting and tooling were developed for the sensor allowing for pipe temperatures up to 750 deg. F. To overcome the small diameter / thick pipe issue, Flexim engineers reconfigured the sensor’s firmware to change from measuring flow rate, and instead measure noise (decibels) as an innovative way to distinguish steam from water.

Flexim’s unique ability to measure the presence of liquid in condensate drain pipes is a revolutionary development. This valuable solution helps customers run longer and safer, minimizing downtime. Share your measurement challenges with process measurement specialists, leveraging your own knowledge and experience with their product application expertise to develop an effective solution.

HVAC Energy Management - Thermal Metering With Non-Invasive Technology

control housing for ultrasonic flow meter thermal energy calculator
Ultrasonic flow measurement is an optimal choice
for thermal metering, with it non-invasive installation.
Image courtesy Flexim Americas Corp.
The modern business climate has, for some time now, been spooling up demand for accountability and, even more so, efficiency. Whether you think of efficiency as "doing more with less" or just avoiding the expenditure of financial, human, or natural resources the end result is the same and calls for similar prerequisites.

We live in a society of buildings, each with a mapped out function. Most buildings are predominantly occupied by people, bringing a requirement to maintain temperature, relative humidity, and air quality at levels of suitable comfort for human occupants. The energy consumption involved with providing that level of comfort stands as a bold line item in the operating expense ledger for any building. That is where accountability and efficiency come in. It is in the building stakeholders' interest to have knowledge regarding rates and quantity of thermal energy usage, as well as efficiency measures of delivered output per unit of input energy.

HVAC (Heating, Ventilation, Air Conditioning) primarily is an endeavor that generates and moves thermal energy throughout an enclosed space. Commercially available technology now allows a building operator to accurately measure that movement of thermal energy throughout a system or building. The process is generally called BTU metering and has a number of justifiable benefits.
  • Real time equipment performance measurement.
  • Sub metering can indicate specific areas of consumption.
  • Ability to directly bill multiple tenants in a single building for their thermal energy usage.
  • Monitor and balance energy flows.
BTU metering essentially involves inlet and outlet temperature measurement of heat transfer liquids, along with their flow rate. While the principle is simple, the intricacies of the measurement methods and equipment accuracy can have a substantial impact on the accuracy, and thus the benefit, of the measurement data. Additionally, adding more instrumentation to an already complex system can create an additional on-going maintenance and calibration burden to retain the necessary levels of accuracy and function. Success at gaining the benefit of the performance data while minimizing the additional maintenance burden due to the instrumentation should be the goal.

One solution calls for the use of clamp on ultrasonic flow meters to measure liquid flow, coupled with temperature measurement in a single unit that will perform necessary calculations and provide output data in useful engineering units. An overarching benefit of the clamp on meter is its non-invasive nature, allowing its retrofit to in-place systems with no disturbance to existing piping. Here are some other characteristics of a highly effective BTU measurement unit:
  • No wear mechanism as part of the flow measurement unit
  • Traceable accuracy of flow and temperature measurements
  • Simple installation in new or retrofit applications without disruption to system operation
  • Reliable and maintenance free operation
  • Accurate measurement from near zero flow rate to maximum system flow
  • Stable sensing with no zero drift
  • Communications protocol to match building energy management system
  • Large storage cache for data, in case of communication failure
  • Common output signals, 4-20 ma or other, usable with selected ancillary equipment
Selecting the right equipment or instrumentation is the most important step along the path of adding measurement capability to increase efficiency. Without a solid stream of reliable data, useful decisions become difficult. Contact a product application specialist and share your goals and challenges. Leverage your own knowledge and experience with their product application expertise to develop an effective solution.