Fuel fired boiler operation can be costly. Maintaining high
combustion efficiency returns substantial cost savings.
Steam and hot water use is prevalent throughout industrial processes. Production of these two media is most commonly accomplished with a boiler, many of which are heated by combustion of fossil fuel. Fuel fired boilers of a certain size become the focus of regulatory requirements for emissions. All boilers consume what would be construed by their owners as large amounts of costly fuel. Because of their high pressure and temperature, and the presence of a controlled combustion within an occupied facility, safety is a paramount concern.

There, fortunately, is a single solution that can help to attain useful goals with the three concerns of safety, fuel cost, and regulatory compliance. Applying an efficiency controller to manage the fuel to air ratio of the combustion system will deliver benefits far in excess of the cost to incorporate the necessary devices. The three basic goals for the fuel air controller are:
  • Maximize fuel efficiency
  • Minimize regulated emissions
  • Maintain safe operating condition
A good portion of all three goals can be accomplished through careful concerted parallel control of combustion air supply and fuel supply. The fuel air ratio must be subject to continual adjustment in response to current air conditions (which can vary on a daily basis) and the level of O2 in the flue gas. Controlling the air fuel ratio supports the following goals:
  • Preventing excess fuel vapors from entering the flue and creating an unsafe condition
  • Providing the correct amount of air to effectively combust the fuel supplied to the burner
  • Preventing excess air flow from reducing net heat transfer to the feedwater
  • Maintaining regulated emissions within required limits
  • Limiting fuel consumption to the minimum necessary to meet demand
Fireye® is a leading manufacturer of flame safeguard controls and burner management systems for commercial and industrial applications throughout the world. Their products, the first of which was developed in the 1930's, enhance the safety and efficiency of all fuel fired burners.

There are numerous capabilities built in to the company's PPC4000 series of fuel air ratio controllers. Some of the more notable include:
  • Precise fuel air ratio attained using parallel control of servos to regulate fuel and air supplies.
  • User selected burner profiles
  • Alarm contacts
  • PID operation
  • An array of inputs and outputs to accommodate sensors and devices needed to monitor and control boiler operation
  • Compatible with other products that provide additional flame and burner monitoring safety
  • Multiple boiler sequencing and cold start thermal shock protection
  • On board boiler efficiency calculation
  • User interface, optional larger touchscreen interface
Glance through just the first two pages of the document below to get a full description of the capability of this compact and comprehensive controller. You can get more detailed information, or get a professional evaluation of your current system efficiency, by contacting the application experts at Classic Controls.


Laser Spectroscopy Applied to Oxygen Measurement



Combining the analytical function of laser spectroscopy with the simple installation package of an industrial transmitter, the Sick TRANSIC100LP provides direct real time in-process oxygen measurements in a wide range of industrial processes. The short video shows how the unit is easy to install and uncomplicated to operate as part of a process measurement and control system.

Fast results and low maintenance are hallmarks of TRANSIC100LP operation. There are no sample prep requirements and no consumables. Sick explains the operating principle of the transmitter in their technical data sheet...
"The TDLS Tunable Diode Laser Spectroscopy is primarily used in high-end gas analyzers and is characterized by its highly selective measurement capability. The oxygen properties are used for O2 measurement: That means O2 atoms in the near infrared range are stimulated at specific wavelengths. A laser diode modulates the radiation precisely over an absorption peak. The high-energy radiation transfers energy to the O2 atoms and the signals becomes weaker. In the measuring probe, the laser beam hits the O2 atoms and is weakened according to the concentrations of oxygen present there. A receiver measures the intensity of the arriving radiation and accurately determines the absorption. One distinct advantage of laser spectroscopy is it´s insensitivity to possible interference. For O2 in particular, there is no absorption of other gases in the range of sampled absorption peaks."
Watch the video for more detail and some application examples. Share your gas analysis requirements and challenges with process measurement specialists, combining your own process knowledge and experience with their product application expertise to develop effective solutions.

Filled Impulse Lines With Pressure Sensors or Gauges

industrial pressure transmitter
Pressure transmitters and gauges are often installed
with impulse lines.
Image courtesy Yokogawa
Pressure sensors intended for use in industrial process measurement and control applications are designed to be robust, dependable, and precise. Sometimes, though, it is necessary or beneficial to incorporate accessories in an installation which augment the performance of pressure sensors in difficult or hazardous environments. There are some scenarios where the sensor must be isolated from the process fluid, such as when the substance is highly corrosive.

A way to aid pressure sensing instruments in situations where direct contact must be avoided is by using a filled impulse line. An impulse line extends from a process pipe of vessel to a pressure measurement instrument or sensor. The line can have a diaphragm barrier that isolates the process fluid from the line, or the line can be open to the process. There are best practices that should be followed in the design and installation of an impulse line to assure that the line provides a useful transmission of the process pressure to the sensor and whatever degree of isolation or protection is needed remains in effect.

The filled impulse line functions via the addition of a non-harmful, neutral fluid to the impulse line. The neutral fluid acts as a barrier and a bridge, allowing the pressure sensing instrument to measure the pressure of the potentially harmful process fluid without direct contact. An example of this technique being employed is adding glycerin as a neutral fluid to an impulse line below a water pipe.

Glycerin’s freeze point is lower than water’s, meaning glycerin can withstand lower temperatures before freezing. The impulse line connected to the water pipe may freeze in process environments where the weather is exceptionally cold, since the impulse line will not be flowing in the same way as the water pipe. Since glycerin has a greater density and a lower freezing point, the glycerin will remain static inside the impulse line and protect the line from hazardous conditions.

The use of an isolating diaphragm negates the need for certain considerations of fill fluid density, piping layout, and the need to create an arrangement that holds the fill fluid in place within the impulse line. System pressure will be transferred across the diaphragm from the process fluid to the fill fluid, then to the pressure sensor. It is important to utilize fluids and piping arrangements that do not affect the accurate transference of the process pressure. Any impact related to the impulse line assembly must be determined, and appropriate calibration offset applied to the pressure sensor reading.

An essential design element of a filled impulse line without an isolating diaphragm is that the fill fluid must be compatible with the process fluid, meaning there can be no chemical reactivity between the two. Additionally, the two fluids should be incapable of mixing no matter how much of each fluid is involved in the combination. Even with isolating diaphragms employed, fluid harmony should still be considered because a diaphragm could potentially loose its seal. If such a break were to occur, the fluids used in filled impulse lines may contact the process fluid, with an impact that should be clearly understood through a careful evaluation.

Share your pressure measurement requirements and challenges with experienced application specialists, combining your own process knowledge and experience with their technical expertise to develop an effective solution.

Digital Valve Positioner

digital valve positioners mounted on linear and rotary valves
D3 digital positioner is suitable for linear or rotary valves
Image courtesy of  Flowserve - PMV
A digital positioner is primarily intended for use with modulating control valves. Full featured units will accommodate single or double acting actuators, as well as rotary and linear valves. A digital positioner is a precision instrument and should be treated with a commensurate amount of care to prevent damage during installation and setup.

The positioner will read a control signal input, such as 4-20 mA. The internal processing of the digital positioner will regulate the operation of air supply and venting valves integral to the positioner, regulating the motive pressure on the actuator and the resulting valve trim position. Positional feedback of the valve position is provided by a potentionmeter.

Units can be provided with one of several different communications options to enable setup and diagnostic information to be transmitted across a network. Good air supply quality and pressure will assure the best positioner performance. Various spindle and bracket arrangements are available to facilitate proper mounting of the digital positioner to the valve actuator.

The use of a digital positioner enables superior modulating valve control and repeatability, along with improved diagnostic information. More detail is contained in the document provided below. Share your fluid control challenges with valve automation experts, combining your own process knowledge and experience with their product application expertise to develop effective solutions.


Thermal Mass Flow Meters for Combustion Efficiency Control and Monitoring

thermal mass flow meter inline style
Example of inline thermal mass flow meter
Image Courtesy Fox Thermal Instruments
Fox Thermal Instruments, a recognized leader in the manufacture of thermal mass flow meters, has authored a white paper entitled "Reduce Energy Costs and Enhance Emissions Monitoring Systems" which provides a technical view of how the use of thermal mass flow measuring technology can be effectively employed on combustion based systems to provide efficient energy usage. Combustion efficiency contributes to the financial benefit of an operation, as well as enabling compliance with emission requirements.

Thermal mass flow measurement is a well regarded mature technology in industrial process measurement and control applications. The instrument returns a mass flow reading by measuring the heat dissipating effect of the media flow on a temperature sensor. Heat transfer is proportional to the mass flow.

The mass flow measurement instruments are very popular for several reasons. They have no moving parts, have a fairly unobstructed flow path, are accurate over a wide range of flow rates, calculate mass flow rather than volume, measure flow in large or small piping systems, and do not need temperature or pressure compensation.

The white paper is provided below for you to read. It is informative and will prove a good investment of time to read. Share your flow measurement challenges of all types with process instrumentation specialists, combining your own process knowledge and experience with their product application expertise to develop effective solutions.


Thoughts on Upside of Outsourcing Industrial Project Work

liquid metering system for pipeline
Many companies that use these liquid metering systems possess
some of the technical and physical resources to design and build
their own. Outsourcing the work can bring the best resources to bear
on the project and free in-house personnel for other tasks.
Photo courtesy Sagebrush Pipeline Equipment
Industrial process measurement and control entails projects, lots of projects. Equipment and instruments that are the life of our processes periodically need modification, replacement, major service or maintenance. Large scale work is generally contracted out for a variety of reasons, not the least of which is that the manpower, equipment, or license and certification requirements are beyond what the stakeholder (the company) may possess . But on smaller projects, an organization is often confronted with the decision of whether to do the work in house or contract it out. There are potential perils and rewards, regardless of the path you take.

The title of this article reveals my leanings on the issue of whether to outsource. Based upon my own project experience and observations of others in their pursuit of project completion, I am generally in favor of it.

Prior to determining whether to use internal or external resources, take the time to document some elemental project requirements.
  • What is the starting condition of the project? It is important to systematically assess the existing conditions, as they have a substantive impact on the scope of work needed to be accomplished to reach the point of completion.
  • What is to be the ending condition of the project, the definition of completion? There must be a defined ending condition that, once achieved, signals that the project is complete. Start with a general statement and add details garnered from various stakeholders. Keep in mind that the end condition will need to satisfy all stakeholders, so their input should be influential.
  • How much time is allowed to complete the work? This pertains to the needs of the company, not the time required to accomplish the task. If there is a deadline for the project, it must be known. An example would be completion of combustion efficiency upgrades prior to the effective date for a new emissions standard. It's not when the work can be done, but when it must be done
  • How much time will be required to complete the work? This may be difficult to ascertain at project inception, but some allowance should be assigned to planning, equipment and material procurement, actual hands-on trade and technical work, startup, testing, commissioning, and final documentation and training. This exercise will help you develop a more detailed picture of what is involved in getting the project completed and how long the timeline might be.
  • What special trade or technical skills will be required? You may need skilled or certified individuals to perform certain tasks. It is essential to know the extent of these resource requirements.
  • Does any of the work require a license or permit? Some extents of modification may require permits from a local jurisdiction and/or licensed trades to perform the work. New work often requires permits. Every jurisdiction has its own set of standards and requirements which must be considered.
Recall that I said document the project requirements. This is important for everyone involved. You want to prevent the drifting of performance benchmarks during the course of the project. This should be especially important if you are the one responsible for project completion. Injections of additional requirements midstream have the potential to destroy your carefully considered plans and result in delays, increased cost, compromised quality, and dissatisfied stakeholders. If somebody wants a change, insist that they be realistic about its impact on the schedule and budget.

There are three major decision factors to consider for in-house or outsourced projects.
  • Technical resources: Do you have people on staff with skills and qualifications that match those that will be needed to accomplish all the tasks comprising the project? That may include substantially more than the mechanics needed to install newly acquired parts and equipment. Consider engineering and design, the production of required documentation, procurement and scheduling of materials and equipment, proactive scheduling and coordination of the various tasks, and general project management.
  • Special equipment and tools: Are there any particular tools, instruments, or equipment that will be required on the project? Does the organization have these resources on hand? If not, how will they be procured, how long does it take, how much does it cost?
  • Available manpower: Are there enough personnel in the organization with the needed skills to complete the work AND is there enough slack available in their schedule to allow a sufficient amount of their time to be devoted to the project to achieve a timely completion? This is critical and applies to both the skilled trade labor and administrative manpower requirements.
An honest and thoughtful consideration of the three areas outlined will likely convince you that, unless the project is small in scale and simple in scope, outsourcing to a contractor with expertise and experience in the work to be accomplished is your best course of action. Sure, dealing with contractors can be difficult and merely outsourcing will not be a panacea for all the challenges presented by any project. However, if a contractor's fulfillment of the three considerations outlined above are better than yours, there is probably advantage in hiring them.

In the big picture, outsourcing can keep your company's resources available to perform tasks more directly related to revenue generation, which is what they were likely hired for in the first place. Outsourcing draws comparatively little from the organization resource pool and, candidly, puts the bulk of the performance burden and the associated aggravation and stress on another organization that is probably better equipped to handled it than you. Done right, it can be a big win for everyone.

Share your process and fluid control projects with experienced professionals and seek out opportunities to be more effective.

Flow Measurement - Sometimes the Simple Solution is Best

variable area flow meter measures and indicates fluid flow directly
These variable area flow meters also permit visible
inspection of flowing media
Courtesy ERDCO Engineering Corp.
For process control and commercial or industrial applications, there are numerous methods of flow measurement from which to choose. Technologies range from very simple applications of physical principles to deployment of very specialized electronics and sensors. The available range of accuracy, response, and cost is quite broad, with a general expectation that higher cost will deliver better performance and accuracy.

Making the best instrument selection for a flow measurement application should include an assessment of what the operators really need in order to safely and effectively run the process or perform the task related to the measurement of fluid flow. Installing instrumentation with capabilities far beyond what is required is almost certainly a waste of financial resources, but may also have an unexpected impact on operators. Through the generation of data that, while accurate, does not provide any actionable information about process condition, operators can be misled, similar to the occurrence of a false or nuisance alarm. Some applications call for high accuracy, some do not. Define your informational needs and select instruments that will meet those needs.

There is a large array of applications that can be satisfied with simpler, less costly measurement technology. These devices often employ turbines or vanes to produce an indication of flow rate. Incorporated into some of the instruments is a means to visually observe the flowing liquid to verify color and clarity. Simple devices sometimes are intended only to indicate the presence of fluid flow, and whether the flow rate is high or low. Configurations are available that allow insertion into lines under pressure (hot tap) through a full port ball valve. Other variants with combinations of features and capabilities abound.

The selection range is enormous, so define your minimum needs first, then search for a compatible product. Your search can be enhanced by contacting an instrumentation specialist. Combining your process expertise with their broad product knowledge will produce effective solutions.